Redoubt wroteHi Safeman
Just out of interest, did John Tann UK undertake any in-house testing on any of their range, specifically taking into account the UL ratings, just as as a comparison of how they would end up compared to UL ratings?
Yes Redoubt, Tann had a test facility at the Borehamwood factory where tests were regularly conducted on test panels of new barrier designs plus on samples of all their new products plus the products of some of our competitors, just as Chubb’s R&D did at Wolverhampton.
The only UK made product which could be considered to have been appropriate for UL testing was the Cashier TL15. For the higher grades the products of the Swedish factory were successfully approved.
Tann was probably the foremost UK supplier to the likes of NCR for their ATM security enclosures and with so many failing with the TL15 units, designed and had approved a UL 291 level 2 TL30×6 unit but the end customers didn’t seem to take up on it.
Tann’s R&D convinced the sales deparment of the inadvisability of putting the likes of the Fortress. Bankers, and even Diamond up to the UL for their highest categories. This decision was justified by the huge costs involved and the peculiarity of a fail from 2 sq.in. gap between the door and body. The cost of preventing this would have been a totally unjustified new strengthened frame design and quite unneccessary in the light of real criminal activity.

The centre picture shows part of the road breaker used on the concrete. The third picture is of a Hilti Core drill test at the LPC test centre where I worked briefly after retirement from Tann.
[unknown]